However, unlike the NCTO contact, the timing action occurs upon de-energization of the coil rather than upon energization. Like the NCTO contact, this type of contact is normally closed when the coil is unpowered (de-energized), and opened by the application of power to the relay coil. In other words, the direction of the contact’s motion (either to close or to open) is identical to a regular NC contact, but there is a delay in the opening direction.īecause the delay occurs in the direction of coil energization, this type of contact is alternatively known as a normally-closed, on-delay:įinally, we have the normally-closed, timed-closed (NCTC) contact. The contact is opened with the application of power to the relay coil, but only after the coil has been continuously powered for the specified amount of time. This type of contact is normally closed when the coil is unpowered (de-energized). Next, we have the normally-closed, timed-open (NCTO) contact. Because the delay occurs in the direction of coil de-energization, this type of contact is alternatively known as a normally-open, off-delay: However, unlike the NOTC contact, the timing action occurs upon de-energization of the coil rather than upon energization. Like the NOTC contact, this type of contact is normally open when the coil is unpowered (de-energized), and closed by the application of power to the relay coil. Next, we have the normally-open, timed-open (NOTO) contact. The following is a timing diagram of this relay contact’s operation: Because the delay occurs in the direction of coil energization, this type of contact is alternatively known as a normally-open, on-delay: In other words, the direction of the contact’s motion (either to close or to open) is identical to a regular NO contact, but there is a delay in closing direction. The contact is closed by the application of power to the relay coil, but only after the coil has been continuously powered for the specified amount of time. This type of contact is normally open when the coil is unpowered (de-energized). Normally-Open, Timed-Closed Contactįirst, we have the normally-open, timed-closed (NOTC) contact. The following is a description of the four basic types of time-delay relay contacts. Time-delay relays can be constructed to delay armature motion on coil energization, de-energization, or both.Time-delay relay contacts must be specified not only as either normally-open or normally-closed but whether the delay operates in the direction of closing or in the direction of opening. This addition gives the relay the property of time-delay actuation. Some relays are constructed with a kind of “shock absorber” mechanism attached to the armature which prevents immediate, full motion when the coil is either energized or de-energized.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |